Sci Rep ; 11(1): 13969, 2021 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-34234187

RESUMO

A label-free electrochemical aptamer-based sensor has been fabricated for alpha-fetoprotein (AFP) detection. Platinum nanoparticles on carboxylated-graphene oxide (PtNPs/GO-COOH) modified screen-printed graphene-carbon paste electrode (SPGE) was utilized as an immobilization platform, and the AFP aptamer was employed as a bio-recognition element. The synthesized GO-COOH helps to increase the surface area and amounts of the immobilized aptamer. Subsequently, PtNPs are decorated on GO-COOH to enhance electrical conductivity and an oxidation current of the hydroquinone electrochemical probe. The aptamer selectively interacts with AFP, causing a decrease in the peak current of the hydroquinone because the binding biomolecules on the electrode surface hinder the electron transfer of the redox probe. Effects of aptamer concentration and AFP incubation time were studied, and the current changes of the redox probe before and after AFP binding were investigated by square wave voltammetry. The developed aptasensor provides a linear range from 3.0-30 ng mL-1 with a detection limit of 1.22 ng mL-1. Moreover, the aptamer immobilized electrode offers high selectivity to AFP molecules, good stability, and sensitive determination of AFP in human serum samples with high recoveries.

2.
Talanta ; 166: 369-374, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28213248

RESUMO

Multi-reverse flow injection analysis (Mr-FIA) integrated with multi-optical sensor was developed and optimized for the simultaneous determination of multi ions; Mn(II), Fe(II), Cu(II) and Fe(III) in water samples. The sample/standard solutions were propelled making use of a four channels peristaltic pump whereas 4 colorimetric reagents specific for the metal ions were separately injected in sample streams using multi-syringe pump. The color zones that formed in the individual mixing coils were then streamed into multi-channels spectrometer, which comprised of four flows through cell and four pairs of light emitting diode and photodiode, whereby signals were measured concurrently. The linearity range (along with detection limit, µgL-1) was 0.050-3.0(16), 0.30-2.0 (11), 0.050-1.0(12) and 0.10-1.0(50)mgL-1, for Mn(II), Fe(II), Cu(II) and Fe(III), respectively. In the interim, the correlation coefficients were 0.9924-0.9942. The percentages relative standard deviation was less than 3. The proposed system was applied successfully to determine targeted metal ions simultaneously in natural water with high sample throughput and low reagent consumption, thus it satisfies the criteria of Green Analytical Chemistry (GAC) and its goals.

3.
Anal Sci ; 31(5): 365-70, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25958864

RESUMO

Microfluidics minimize the amounts of reagents and generate less waste. While microdevices are commonly single-sided, producing a substrate with microchannels on multiple surfaces would increase their usefulness. Herein, a polymethymethacrylate substrate incorporating microchannel structures on two sides was sandwiched between two polydimethylsiloxane sheets to create a multi-analysis device, which was used for the spectrophotometric analysis of the ferrous ion (Fe(2+)) and the ferric ion (Fe(3+)), by utilizing colorimetric detection. To monitor the signals from both channel networks, dual optical sensors were integrated into the system. The linear ranges for Fe(2+) and Fe(3+) analyses were 0.1 - 20 mg L(-1) (R(2) = 0.9988) and 1.0 - 40 mg L(-1) (R(2) = 0.9974), respectively. The detection limits for Fe(2+) and Fe(3+) were 0.1 and 0.5 mg L(-1), respectively. The percent recoveries of Fe(2+) and Fe(3+) were 93.5 - 104.3 with an RSD < 8%. The microdevice demonstrated capabilities for simultaneous analysis, low waste generation (7.2 mL h(-1)), and high sample throughput (180 h(-1)), making it ideal for greener analytical chemistry applications.

4.
Talanta ; 106: 350-9, 2013 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-23598137

RESUMO

In this research, a greener chromatography employing a short column, Zorbax SB C18 cartridge (12.5 × 4.6 mm, 5 µm) commonly used as a guard column in a reverse phase high performance liquid chromatography (RP-HPLC), was utilized as the analytical column in conjunction with a more eco-friendly micellar mobile phase of sodium dodecyl sulfate (SDS) for separation tertiary mixtures of local anesthetics and antihistamines; and binary mixture of colds drugs; and quaternary mixture of some parabens with different separation conditions. The chromatographic behavior of these analytes was studied to demonstrate separation efficiency of this guard column in a micellar mobile phase. Moreover, this column and SDS mobile phase was exploited for determination of parabens in 64 samples of cosmetic product, both those that were produced locally in the community and those that were commercially manufactured. Linear calibration graphs of the parabens as detected at 254 nm were obtained in the range of 1-100 µmol L(-1) with R(2)>0.9990. Percentage recoveries were 92.4-109.2 with %RSD<3, and the limit of detection and quantitation were 0.04-0.10 and 0.20-0.80 µmol L(-1), respectively. This analytical system is not only greener but also faster and employing simpler sample preparation than a conventional liquid chromatographic system.


Assuntos
Anestésicos Locais/análise , Cromatografia de Fase Reversa/métodos , Cosméticos/química , Química Verde , Antagonistas dos Receptores Histamínicos/análise , Parabenos/análise , Calibragem , Cromatografia de Fase Reversa/instrumentação , Misturas Complexas/química , Humanos , Limite de Detecção , Micelas , Dodecilsulfato de Sódio
5.
Anal Sci ; 28(7): 651-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22790365

RESUMO

A simple and inexpensive method for fabricating a microfluidic platform was developed. A printed circuit board (PCB) was used to make a master mold for replicating a polydimethylsiloxane (PDMS) microchannel. The master mold was fabricated by a simple photolithographic method, employing a photoresist dry film. The process did not use hazardous chemicals, a clean room or any expensive instrument. The PDMS microchannel was clamped with polymethylmethacrylate (PMMA) plates, where a light emitting diode (LED) as a light source and a light dependent resistor (LDR) as a light sensor were attached to form a simple optical sensor. The system was successfully employed as a micro flow injection analysis for the determination of glutathione in dietary supplement samples. A linear calibration graph in the range of 5.0 - 60.0 mg L(-1) glutathione was obtained with a detection limit of 0.01 mg L(-1). The system provided a sample throughput of 48 h(-1), with microliter consumption of the reagent.


Assuntos
Colorimetria/instrumentação , Análise de Injeção de Fluxo/instrumentação , Glutationa/análise , Técnicas Analíticas Microfluídicas/métodos , Fenômenos Ópticos , Integração de Sistemas , Colorimetria/economia , Cobre/química , Análise Custo-Benefício , Suplementos Nutricionais/análise , Equipamentos e Provisões Elétricas , Análise de Injeção de Fluxo/economia , Técnicas Analíticas Microfluídicas/instrumentação
6.
Talanta ; 84(3): 745-51, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21482277

RESUMO

Ceric ammonium nitrate has been used for qualitative analysis of ethanol. It forms an intensely colored unstable complex with alcohol. In this work, a simple flow injection (FI) colorimetric method was developed for the determination of ethanol, based on the reaction of ethanol with ceric ion in acidic medium to produce a red colored product having maximum absorption at 415 nm. Absorbance of this complex could be precisely measured in the FI system. A standard or sample solution was injected into a deionized water donor stream and flowed to a gas diffusion unit, where the ethanol diffused through a gas permeable membrane made of plumbing PTFE tape into an acceptor stream to react with ceric ammonium nitrate in nitric acid. Color intensity of the reddish product was monitored by a laboratory made LED based colorimeter and the signal was recorded on a computer as a peak. Peak height obtained was linearly proportional to the concentration of ethanol originally presented in the injected solution in the range of 0.1-10.0% (v/v) (r(2)=0.9993), with detection limit of 0.03% (v/v). With the use of gas diffusion membrane, most of the interferences could be eliminated. The proposed method was successfully applied for determination of ethanol in some alcoholic beverages, validating by gas chromatographic method.

7.
Talanta ; 72(1): 126-31, 2007 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-19071592

RESUMO

Greener analytical method using micro flow system for the determination of Cu(II) in wastewater samples was designed and investigated. The micro flow system consisted of a planar glass chip with poly(dimethylsiloxane) (PDMS) top plate and fixed with fiber optic probe as optical sensor for monitoring of Cu(II) that reacted with 2-carboxy-2'-hydroxy-5'-sulfoformazyl benzene (zincon) on the chip at 605nm. This design gave a satisfied sensitivity with a linear calibration graph over the range of 0.1-3.0mugmL(-1) of Cu(II) and correlation coefficient 0.9991. The percentage relative standard deviation was 2.5 for 10-replicate measurements and the limit of detection (LOD) was 0.1mugmL(-1). This system has been successfully applied to the determination of Cu(II) in wastewaters from electroplating industry with less reagents and samples consumption and diminutive waste generation.

8.
Talanta ; 73(1): 46-53, 2007 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-19071848

RESUMO

A simple, inexpensive and reagent-less colorimetric micro flow analysis (microFA) system was implemented in a polymethyl methacrylate (PMMA) micro fluidic manifold. A T-shaped micro channel on a PMMA chip was fabricated by laser ablation and topped with molded polydimethylsiloxane (PDMS). The fabricated microFA system was integrated with the optical components as detector and applied to the determination of iron in water samples. It is based on the measurement of Fe(III)-nitroso-R salt complex at 720 nm formed by the reaction between Fe(III) and nitroso-R salt in an acetate buffer solution pH 5. The proposed microFA consumed very small amount of reagent and sample, it released waste of less than 2.0 mL h(-1). The relative standard deviation (R.S.D.) was less than 2% (n=11) with the recovery of 98.7+/-0.12 (n=5). The linear range for the determination of iron in water samples was over the range of 0.05-4.0 microg mL(-1) with a correlation coefficient (r(2)) of 0.9994. The limit of detection (3sigma) and limit of quantitation (10sigma) were 0.021 microg mL(-1) and 0.081 microg mL(-1), respectively with a sample throughput of 40 h(-1).

9.
Analyst ; 131(4): 501-8, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16568166

RESUMO

A novel ultrasonic flow injection chemiluminescence (FI-CL) manifold for determining hydrogen peroxide (H2O2) has been designed and evaluated. Chemiluminescence obtained from the luminol-H2O2-cobalt(II) reaction was enhanced by applying 120 W of ultrasound for a period of 4 s to the reaction coil in the FI-CL system and this enhancement was verified by comparison with an identical manifold without ultrasound. The system was developed for determining ultra-trace levels of H2O2 and a calibration curve was obtained with a linear portion over the range of 10-200 nmol L(-1) H2O2 (correlation coefficient 0.9945). The detection limit (3sigma) and the quantification limit (LOQ) were found to be 1 x 10(-9) and 3.3 x 10(-9) mol L(-1) respectively and the relative standard deviation was 1.37% for 2 x 10(-7) mol L(-1) H2O2 (n = 10). The method was applied to the determination of trace amounts of H2O2 in purified water and natural water samples without any special pre-treatments.

10.
J Pharm Biomed Anal ; 31(4): 629-38, 2003 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-12644189

RESUMO

A micellar liquid chromatography (MLC) procedure was developed for the simultaneous separation and determination of lidocaine hydrochloride (LD HCl) and tolperisone hydrochloride (TP HCl) using a short-column C18 (12.5 mm x 4.6 mm, 5 microm), sodium dodecyl sulfate (SDS) with a small amount of isopropanol, and diode array detector. The optimum conditions for the simultaneous determination of both drugs were 0.075 mol l(-1) SDS-7.5% (v/v) isopropanol with a flow rate of 0.7 ml min(-1) and detection at 210 nm. The LOD (2S/N) of LD HCl was 0.73 ng 20 microl(-1), whereas that of TP HCl was 1.43 ng 20 microl(-1). The calibration curves for LD HCl and TP HCl were linear over the ranges 0.125-500 microg ml(-1) (r(2)=0.9999) and 1.00-500 microg ml(-1) (r(2)=0.9997), respectively. The %recoveries of both drugs were in the range 98-103% and the %RSD values were less than 2. The proposed method has been successfully applied to the simultaneous determination of TP HCl and LD HCl in various pharmaceutical preparations.